Gene Bio-Application Ltd. (GeBA) develops and markets unique tools with research applications in molecular biology and medicine.
Founded in May of 1999 by molecular biology researchers seeking to create solutions to needs they identified in their own research practice, GeBA has since established a range of products based on a profound commitment to innovation, quality and reliability.
The product range continues to expand, targeting areas of bio-molecular research requiring rapid, reliable, and cost effective solutions. Products are developed, industrialized, and manufactured in GeBA Laboratories, and marketed worldwide by a network of distributors and OEM agreements.
The most convenient sample loading and unloading in the market.
Floating rack and supporting trays make high throughput easy.
Low cost single use, single step unit; no cleaning or autoclaving.
70% recovery of protein & over 90% recovery of DNA / RNA from PAGE
Available in a variety of volume and MWCO options.
Guaranteed Ultra Clean; EDTA treated and free of any contaminants.
Now available with an Oligo PAGE purification protocol yielding over 90% Oligo recovery rate from PAGE
* Please note that not all MWCO are available in each size of GeBAflex-tube.
See list of available GeBAflex Tube Kits below.
MWCO | Units Qty. | Catalog Num. |
6,000-8,000 | 10 | D070-6-10 |
6,000-8,000 | 30 | D070-6-30 |
6,000-8,000 | 50 | D070-6-50 |
6,000-8,000 | 100 | D070-6-100 |
12,000-14,000 | 10 | D070-12-10 |
12,000-14,000 | 30 | D070-12-30 |
12,000-14,000 | 50 | D070-12-50 |
12,000-14,000 | 100 | D070-12-100 |
25,000 | 5 | D070-25-5 |
MWCO | Units Qty. | Catalog Num. |
3,500 | 5 | D030 |
3,500 | 15 | D035 |
3,500 | 50 | D030-50 |
3,500 | 100 | D030-100 |
6,000-8,000 | 5 | D040 |
6,000-8,000 | 15 | D045 |
6,800-8,000 | 50 | D040-50 |
6,000-8,000 | 100 | D040-100 |
12,000-14,000 | 5 | D050 |
12,000-14,000 | 15 | D055 |
12,000-14,000 | 50 | D050-50 |
12,000-14,000 | 100 | D050-100 |
25,000 | 5 | D060-25-5 |
50,000 | 5 | D060-50-5 |
MWCO | Volume | Units Qty. | Catalog Num. |
1,000 | 10mL | 5 | D080-1/10-5 |
1,000 | 15mL | 5 | D080-1/15-5 |
1,000 | 20mL | 5 | D080-1/20-5 |
3,500 | 10mL | 10 | D080-3,5/10-10 |
3,500 | 15mL | 10 | D080-3,5/15-10 |
3,500 | 20mL | 10 | D080-3,5/20-10 |
6,000-8,000 | 10mL | 10 | D080-6/10-10 |
6,000-8,000 | 15mL | 10 | D080-6/15-10 |
6,000-8,000 | 20mL | 10 | D080-6/20-10 |
12,000-14,000 | 10mL | 10 | D080-12/10-10 |
12,000-14,000 | 15mL | 10 | D080-12/15-10 |
12,000-14,000 | 20mL | 10 | D080-12/20-10 |
Mini: 10-250 μl
Midi: 50-800 μl
Maxi: 0.1-3 ml
Mega: 3-20 ml
Wide range of options
1,000-50,000 MWCO
Single floating rack in a single beaker can process up to
63 Mini / 35 Midi / 20 Maxi GeBAflex-tubes
Electro Elution of up to 100 samples simultanioulsy
Exceptionally High Molecule Recovery Yield:
DNA or RNA from agarose gel: 80-90%
Oligo, DNA or RNA from PAGE: 80-90%
Protein from SDS-PAGE: 50-70%
EDTA treated and free of RNase, DNase, PCR product, sulfur or heavy metal contaminants.
Sterile conditions available for custom orders.
24 month shelf life at room temperature
(for most models, see storage conditions for more details).
secure and convenient loading & unloading with standard pipette tip, surpasses any other product in the market!
Single step, single use and low cost.
Reduced human error and contamination – no need for cleaning and autoclaving.
GeBAflex-tube caps option improves dialysis effect
by maximizing liquid surface membrane contact.
High throughput Dialysis or buffer exchange
peptide dialysis small as 10 amino acids
pH and buffer adjustment of sample solution, protein extract or cell extract
Large scale protein dialysis such as antibodies and recombinant protein purification
Sample concentration
virus particles purification
Removal of contaminating micro molecules
Tissue culture extract purification
Removal of salts, surfactants, ethidiumbromide, urea, solvents and detergents
Preparation of protein samples for MALDI-MS.
Complex formation studies (protein-protein, protein-DNA and protein-RNA)
Extraction of proteins, RNA, DNA or oligos (as small as 15 nt up to over 10kb) from polyacrylamide, agrose or any gel matrix in any running buffer.
Extraction of protein-protein, DNA-protein or RNA-protein complexes.
2D gel dots extraction.
High throughput Electro elution from 1D and 2D gel (supporting tray fits most horizontal electrophoresis units on the market).
GeBAflex-tube kit must be stored in a dry place at room temperature (15-25°C). Under these conditions, GeBAflex-tube kit can be stored for up to 24 months without any deterioration in performance and quality. For longer storage time, it is recommended that the GeBAflex-tube kit be stored in a cool place (refrigerator), at relative humidity of 35% at least. GeBAflex Tubes with MWCO of 1,000 / 25,000 / 50,000 are delivered wet and must be stored at 4°C.
GeBAflex-tube kit is developed, designed and sold for research purposes only. It is not to be used for human diagnostic purposes or drug production nor for producing any substance intended to be administered to humans unless expressly cleared for that purpose by the Food and Drug Administration in the USA or the appropriate regulatory authorities in the country of use. All due care and attention should be exercised in the handling of materials described in this text.
The performance of GeBAflex-tube kit is regularly monitored. GeBAflex-tube kit is tested by using it for extraction of Proteins, DNA and RNA fragments of various sizes from either agarose or polyacrylamide gel. GeBAflex-tube kit is tested also for simple dialysis of salts or buffer exchange. The quality of the isolated Protein, DNA and RNA fragments or of the sample after dialysis is checked by several assays commonly used for proteins, nucleic acids and dialysis. Determining the recovery from a specific amount of loaded sample tests the quality and efficiency of the GeBAflex-tube membrane.
Ideal for protein (native/denatured).
No assembly, buffer leakage or cross contamination.
No need for adapters or special loading tips.
Sharper bands and totally smile free separation provide clearer more accurate results.
12 month shelf life guaranteed.
Neutral pH and SDS Free.
AA Gel % | Units Qty. | Catalog Num |
10% | 2 | 10G-0010-2 |
10% | 10 | 10G-0010-10 |
12% | 2 | 10G-0012-2 |
12% | 10 | 10G-0012-10 |
4-12% | 2 | 10G-0412-2 |
4-12% | 10 | 10G-0412-10 |
8-16% | 2 | 10G-0816-2 |
8-16% | 10 | 10G-0816-10 |
4-20% | 2 | 10G-0420-2 |
4-20% | 10 | 10G-0420-10 |
AA Gel % | Units Qty. | Catalog Num |
10% | 2 | 15G-0010-2 |
10% | 10 | 15G-0010-10 |
12% | 2 | 15G-0012-2 |
12% | 10 | 15G-0012-10 |
4-12% | 2 | 15G-0412-2 |
4-12% | 10 | 15G-0412-10 |
8-16% | 2 | 15G-0816-2 |
8-16% | 10 | 15G-0816-10 |
4-20% | 2 | 15G-0420-2 |
4-20% | 10 | 15G-0420-10 |
AA Gel % | Units Qty. | Catalog Num |
10% | 2 | 3G-0010-2 |
10% | 10 | 3G-0010-10 |
12% | 2 | 3G-0012-2 |
12% | 10 | 3G-0012-10 |
4-12% | 2 | 3G-0412-2 |
4-12% | 10 | 3G-0412-10 |
8-16% | 2 | 3G-0816-2 |
8-16% | 10 | 3G-0816-10 |
4-20% | 2 | 3G-0420-2 |
4-20% | 10 | 3G-0420-10 |
AA Gel % | Units Qty. | Catalog Num |
10% | 2 | 2G-0010-2 |
10% | 10 | 2G-0010-10 |
12% | 2 | 2G-0012-2 |
12% | 10 | 2G-0012-10 |
4-12% | 2 | 2G-0412-2 |
4-12% | 10 | 2G-0412-10 |
8-16% | 2 | 2G-0816-2 |
8-16% | 10 | 2G-0816-10 |
4-20% | 2 | 2G-0420-2 |
4-20% | 10 | 2G-0420-10 |
10%
12%
4-12%
8-16%
4-20%
1+1 (700 µl/well)
1+2 (200 µl/well)
10 (40 µl/well)
15 (25 µl/well)
Horizontal operation eliminates the nuisance and time consumption of assembly and buffer spills from the top to bottom buffer chamber.
GeBA Runner minimizes heat generated inside the gel while ensuring its equal distribution.
To increase the security of the system, the GeBA Runner includes a built in proximity sensor, located in the protective safety cover, which shuts down power to the unit if the cover is removed.
No adapters are required for use and most power supply units can power multiple GeBA Runners simultaneously (overall current supplied must be limited to 160V).
60 minute run time.
Significant savings of running buffer
(the system uses a total of 180 ml).
Standard membrane transfer buffer.
Reinforced sample wells eliminate damage when removing comb and loading samples.
Robust sample well dividers won’t deform or fall over.
Elimination of cross contamination of sample wells.
Effortless cassette opening.
Foolproof well access.
Analysis of Proteins (under both native and denatured electrophoresis conditions), with the same standard GeBaGel and Tris-Glycine running buffer.
Dependable, Sharp Bands and Smile Free Separation for outstanding clarity and results across all analyses
GeBaRunner Dimensions: 165 X 147 X 45 mm (L x W x H)
Maximum Voltage: 200 V DC
Operating Temperature: 2°C – 40°C
Maximum Power: 20 W
Maximum Current: 100 mA
Degree of Protection: IPX5
GeBA Gels are shipped at ambient temparature must be stored in a dry place at 4°C. Under these conditions, GeBA Gel can be stored for up to 12 months from the production date without any deterioration in performance and quality. Do not Freeze GeBA Gels.
GeBA Gel and the GeBA Runner have been developed, designed and sold for in-vitro research purposes only, namely performance of PAGE. It is not to be used for human diagnostic purposes or clinical procedures. Gloves must be worn at all times when handling GeBA Gel; exercise all due care and attention in the handling of materials described in this text.
The performance of GeBAflex-tube kit is regularly monitored. GeBAflex-tube kit is tested by using it for extraction of Proteins, DNA and RNA fragments of various sizes from either agarose or polyacrylamide gel. GeBAflex-tube kit is tested also for simple dialysis of salts or buffer exchange. The quality of the isolated Protein, DNA and RNA fragments or of the sample after dialysis is checked by several assays commonly used for proteins, nucleic acids and dialysis. Determining the recovery from a specific amount of loaded sample tests the quality and efficiency of the GeBAflex-tube membrane.