Total Phenols Colorimetric Assay Kit (Plant Samples)

Catalogue Number: E-BC-K354-S-ELA

Manufacturer:Elabscience
Shelf Life:6 months
Type:Detection Kit
Shipping Condition:Blue Ice
Storage Condition:2-8°C
Unit(s): 100 assays, 200 assays
Range: 0.73-150 µg/mL
Sensitivity: 0.73 µg/mL
Sample type: Tissue
Sample size:

Description

Description: Application This kit can be used to measure the total phenols content in plant tissue samples. Detection significance Plant total phenol is a common secondary natural metabolite in plants. There are several kinds of phenolic compounds, such as hydroxybenzoic acid, hydroxy cinnamic acid, flavonoids, chalcone, flavonoids, lignin, coumarin and astragalus. Phenolic compounds are antioxidants that delay or prevent oxidation and oxygen radical reactions. Detection principle Under alkaline conditions, tungsten-molybdenum acid can be reduced by phenols and produce blue compounds, which has a characteristic absorption peak at 760 nm. The content of total phenols in sample can be calculated indirectly by measuring the absorbance at 760 nm. Experimental instrument Incubator, 40 Mesh sieve, Ultrasonic cell disruptor, Centrifuge, Spectrophotometer (760 nm) Pretreatment of sample 1. Take fresh plant tissue (5-10 g), rinse the surface with distilled water and dry with filter paper. Then dry to constant weight in a vacuum drying oven at 40°C (The difference between the two weights should be less 0. 3 mg). Crush and screen with 40 mesh sieve, sealed at room temperature. 2. Weigh 0.1 g crushed sample and add 2.5 mL of 60% ethanol. Treat the sample with sonication (power: 300W, 3 seconds/time, interval for 4 seconds, total: 30 min). Centrifuge at 10000 g for 10 min at 25°C. Take the supernatant for detection. Operation steps 1. The dilution of standard Dilute 1 mg/mL o-dihydroxybenzene solution with double distilled water to a serial concentration. The recommended dilution gradient is as follows: 150, 120, 100, 80, 40, 20, 0 µg/mL. 2. Operation table Technical parameter 1. The sensitivity of the kit is 0.73 µg/mL. 2. The intra-assay CV is 1.9% and the inter-assay CV is 2.5%. 3. The recovery of the kit is 101%. 4. The detection range of the kit is 0.73-150 µg/mL. Notes 1. The kit is for scientific research only. 2. Instructions should be followed strictly, changes of operation may result in unreliable results. 3. The validity of kit is 6 months. 4. Do not use components from different batches of kit. 5. O-dihydroxybenzene standard solution should be prepared freshly, as it is easily oxidized.

Additional Text

2-8°C

Price
£141.00


Find out about delivery

SUPPORT

outstanding technical support

PRODUCT

we offer a full product guarantee

DELIVERY

we offer free delivery to UK universities and non profit organisations